Search

Search Criteria

 
 
 
 

Products meeting the search criteria

Sort By:  
• Stainless steel IP68 low profile load cell • Hermetically sealed • Suitable for hopper, platform and pallet scales • Integrated static overload protection up to 13t
৳0.00  Inc Tax
Stainless steel IP67 single-point load cell Suitable for weighing equipment like platform and belt scales. Maximum platform size: 400 x 400 mm High accuracy. High reliability. Current calibrated (SC-option). Model: B6N Class: C3 Resistance: Input - 384Ω ± 4Ω Output - 350Ω ± 3.5Ω ​Brand: Zemic Mfg: Zemic Europe. (B.V Netherland) Origin: Assembled in China
৳0.00  Inc Tax
Used in Single Point Platform, Automated servo belt system, PLC Application, Conveyer system, small floor scale platform
৳0.00  Inc Tax
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
Single Point Platform, Automated servo belt system, PLC Application
৳0.00  Inc Tax
Used in Single Point Platform, Automated servo belt system, PLC Application
৳0.00  Inc Tax
Used in 4 Point Platform, Hopper Scale, Automated servo belt system, PLC Applications
৳0.00  Inc Tax
Used in Single Point Platform, Automated servo belt system, PLC Application, Conveyer system, small floor scale platform.
৳0.00  Inc Tax
BM24R (BM24R)
• Stainless steel IP68 low profile load cell • Hermetically sealed • Suitable for hopper, platform and pallet scales • Integrated static overload protection up to 13t
৳0.00  Inc Tax
B6N Loadcell (B6N)
Stainless steel IP67 single-point load cell
Suitable for weighing equipment like platform and belt scales.
Maximum platform size: 400 x 400 mm
High accuracy.
High reliability.
Current calibrated (SC-option).
Model: B6N      Class: C3
Resistance:
Input - 384Ω ± 4Ω  Output - 350Ω ± 3.5Ω
​Brand: Zemic 
Mfg: Zemic Europe. (B.V Netherland) 
Origin: Assembled in China
Available Models:
CapacityAccuracyFull Article Description
8kgC3/C4B6N-C3/C4-8kg-1B6
10kgC3/C4B6N-C3/C4-10kg-1B6
15kgC3/C4B6N-C3/C4-15kg-1B6
20kgC3/C4B6N-C3/C4-20kg-1B6
30kgC3/C4B6N-C3/C4-30kg-1B6
50kgC3B6N-C3-50kg
75kgC3B6N-C3-75kg
100kgC3B6N-C3-100kg
150kgC3B6N-C3-150kg
200kgC3B6N-C3-200kg
Technical Specifications of FM1263
Accuracy ClassOIML R60 C3, OIML R60 C4
Output Sensitivity ( FS )mV/V2.0 ± 0.2
Maximum Capacity ( Emax )kg8, 10, 15, 20, 30, 50, 75, 100, 150, 200
Max. Number of Load Cell IntervalsnLC3000, 4000
Ratio of min. LC Verification IntervalY = Emax / Vmin10000, 15000
Combined Error%FS≤± 0.023; ≤± 0.018
Creep Error (30 minutes)%FS≤± 0.016; ≤± 0.012
Temperature Effect on Zero (ZTC)%FS/10°C≤± 0.015; ≤± 0.010
Temperature Effect on Sensitivity (STC)%FS/10°C≤± 0.011; ≤± 0.009
Zero balance %FS≤± 1.5
Safe overload%FS150
Ultimate Overload%FS300
Maximum Deflectionmm0.1t – 0.2t: 0.3 0.5t – 5t: ~ 1.2 10t: 0.8
Excitation, Recommended VoltageV5 ~ 12
Excitation, Maximum VoltageV18
Input ResistanceΩ384 ± 4
Output ResistanceΩ350 ± 3.5
Insulation Resistance ≥5000
Compensated Temperature°C-10 ~ 40
Operating Temperature°C-35 ~ 65
Storage Temperature°C-40 ~ 80
Load Cell Weightkg0.1t – 2.0t: ~ 0.9; 2.5t – 5t: ~ 1.7; 10t: ~ 3.6
Element MaterialStainless steel
Ingress Protection (acc. to EN 60529)IP67
Recommended Torque on Fixation BoltsNmM12: 100 M18:200 M24:700
ATEX Classification (optional)II 1G Ex ia IIC T4 Ga II 1D Ex ia IIIC T 200 135°C Da II 3G Ex ic IIC T4 Gc
Stainless steel IP67 single-point load cell Suitable for weighing equipment like platform and belt scales. Maximum platform size: 400 x 400 mm High accuracy. High reliability. Current calibrated (SC-option). Model: B6N Class: C3 Resistance: Input - 384Ω ± 4Ω Output - 350Ω ± 3.5Ω ​Brand: Zemic Mfg: Zemic Europe. (B.V Netherland) Origin: Assembled in China
৳0.00  Inc Tax
NEA Loadcell (NEA)
Short Description:
Aluminum-alloy IP65 single point load cell
Colourless anodized
Suitable for single and double load cells structured platform scales
Maximum platform size: 600 x 600 mm
A 1000 Ohm type available (R1) but is excluded from OIML
Manufacturer:
Yide Sensors Inc.
Origin:
Made in Australia
Available Capacity:
Capacity Accuracy Full Article Description
50kg C3 NEA-50kg
100kg C3 NEA-100kg
150kg C3/C4 NEA-150kg
200kg C3/C4 NEA-200kg
250kg C3/C4 NEA-250kg
300kg C3/C4 NEA-300kg
500kg C3/C4 NEA-500kg
Technical Specifications of NEA
Accuracy Class OIML R60 C3, OIML R60 C4
Output Sensitivity ( FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) kg 50, 100, 150, 200, 250, 300, 500, 600; 150, 200, 250, 300, 500, 600
Max. Number of Load Cell Intervals nLC 3000, 4000
Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000
Combined Error %FS ≤± 0.02
Creep Error (30 minutes) %FS ≤± 0.02
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.0230; ≤± 0.0175
Minimum dead load Of Emax 0%
Safe overload Of Emax 150 %
Ultimate Overload Of Emax 300 %
Zero balance Of FS ± 2.0 %
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 750±6
Output Resistance Ω 700±3
Insulation Resistance 5000 (at 50VDC)
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Element Material Aluminum
Ingress Protection (acc. to EN 60529) IP65
Recommended Torque on Fixation Bolts Nm M8:25
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6mm
Cable length: 3m
Shield connected to element
Cable jacket in PVC
Wiring Instruction:
Input(Positive) - Red
Output(Positive) - Green
Output(Negative) - Blue
Input(Negative) - Yellow
Used in Single Point Platform, Automated servo belt system, PLC Application, Conveyer system, small floor scale platform
৳0.00  Inc Tax
HM9B Loadcell (Analog HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer:
Zemic Europe. (B.V Netherland)
Origin:
Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description
10 Ton C3 HM9B-C3-10t-12B-2-FH
20 Ton C3 HM9B-C3-20t-12B-2-FH
25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH
30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH
40 Ton C3 HM9B-C3-40t-16B-2-FH
50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3
Output Sensitivity ( FS ) mV/V 2.0 ± 0.002
Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500
Combined Error %FS ≤± 0.02
Creep Error (30 minutes) %FS ≤± 0.02
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02
Zero Balance %FS ≤± 1.5
Safe Overload %FS 150
Ultimate Overload %FS 300
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 700 ± 7
Output Resistance Ω 703 ± 4
Insulation Resistance (50V) ≥5000
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP68
Recommended Torque on Fixation Bolts Nm 1100
ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) - White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
HM9B Loadcell (Digital HM9B)
Short Description:
Nickel-plated alloy steel IP68 dual shear beam
High accuracy
Suitable for trucks, tracks, hoppers and other electronic weighing devices
Current calibrated (sc-option)
Manufacturer:
Zemic Europe. (B.V Netherland)
Origin:
Assembled in China
Available Capacity:
Capacity Accuracy Full Article Description
10 Ton C3 HM9B-C3-10t-12B-2-FH
20 Ton C3 HM9B-C3-20t-12B-2-FH
25 Ton C3 HM9B-C3-25t-20B(-SC) -2-FH
30 Ton C3 HM9B-C3-30t-20B(-SC) -2-FH
40 Ton C3 HM9B-C3-40t-16B-2-FH
50 Ton C3 HM9B-C3-50t-16B-2-FH
Technical Specifications HM9B
Accuracy Class OIML R60 C3
Output Sensitivity ( FS ) mV/V 2.0 ± 0.002
Maximum Capacity ( Emax ) kg 10, 20, 25 30, 40, 50
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / vmin 15000, 7500
Combined Error %FS ≤± 0.02
Creep Error (30 minutes) %FS ≤± 0.02
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.02
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.02
Zero Balance %FS ≤± 1.5
Safe Overload %FS 150
Ultimate Overload %FS 300
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 700 ± 7
Output Resistance Ω 703 ± 4
Insulation Resistance (50V) ≥5000
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Load Cell Weight kg 10t: 15 20t – 40t: ~17 50t: 25
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP68
Recommended Torque on Fixation Bolts Nm 1100
ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G Ex nL IIC T4
Wiring:
Cable type: Shielded, 4 conductor cable, conductor AWG 24
Cable diameter: Ø 5.5mm
Cable length: 16m (standard), 12m & 20m lengths also available
Cable jacket: PVC
Shield not connected to the element
Wiring Instruction:
Input(Positive) - Red
Input (Negative) - Black
Output(Positive) - Green
Output(Negative) – White
Shield - Gray
Used in weighing applications for Trucks, vehicles, Transport Vehicles, and heavyweight products-based Scales. It is placed in between the civil structure and the mechanical structure. The weight of a vehicle is measured by a converted signal coming out from its transducer.
৳0.00  Inc Tax
UH62 Loadcell (UH62)
Short Description:
Nickel plated alloy steel IP66 single point load cell
Bending beam
Suitable for belt, platform and other electronic weighing devices
Maximum platform size:
1. for 50kg-200kg: 400 x 400 mm
2. for 250kg-500kg: 600 x 800 mm
3. for 750kg-2t: 1200 x 1200 mm
Manufacturer:
Yide Sensors Inc.
Origin:
Made in Australia
Available Models:
Capacity Accuracy Full Article Description
100kg C3 UH62-C3-100kg-3B6
150kg C3 UH62-C3-150kg-3B6
200kg C3 UH62-C3-200kg-3B6
250kg C3 UH62-C3-250kg-3B6
500kg C3 UH62-C3-500kg-3B6
750kg C3 UH62-C3-750kg-3B6
1000kg C3 UH62-C3-1000kg-3B6
2000kg C3 UH62-C3-2000kg-3B6
Technical Specifications of UH62
Accuracy Class C3
Output Sensitivity ( FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) Kg 100, 150, 200, 250, 500, 750, 1000, 2000
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / Vmin 7500
Combined Error %FS ≤± 0.020
Minimum dead load Of Emax 0%
Safe overload Of Emax 150 %
Ultimate overload300 % Of Emax 300 %
Zero balance Of FS < ± 1.0 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum V 18
Input Resistance Ω 406 ± 3
Output Resistance Ω 350 ± 3
Insulation Resistance ≥5000 (at 50VDC)
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP66
Recommended Torque on Fixation Bolts Nm M12:75; M16:200
ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6.2mm
Standard cable length: 3m
Shield not connected to element
Wiring Instruction:
Input (Positive) - White
Sense (Positive) - Brown
Output (Positive) - Red
Output (Negative) - Black
Sense (Negative) - Green
Input (Negative) - Yellow
Dimension Wise Capacity:
Dimension Capacity B B1 H H1 H2 L L1 L2 M
50-200kg 44 24 75 50 30 156 112 14 M12
250-500kg 60 36 95 70 30 146 110 11 M12
750kg-2000kg 76 46 125 95 65 176 110 24 M16
Single Point Platform, Automated servo belt system, PLC Application
৳0.00  Inc Tax
H6F Load Cell (H6F)
Short Description:
Nickel plated alloy steel IP66 single point load cell
Bending beam
Suitable for belt, platform and other electronic weighing devices
Maximum platform size:
1. for 50kg-200kg: 400 x 400 mm
2. for 250kg-500kg: 600 x 800 mm
3. for 750kg-2t: 1200 x 1200 mm
Manufacturer:
Zemic Europe
Origin:
B.V Netherland
Available Models:
Capacity Accuracy Full Article Description
100kg C3 H6F-C3-100kg-3B6
150kg C3 H6F-C3-150kg-3B6
200kg C3 H6F-C3-200kg-3B6
250kg C3 H6F-C3-250kg-3B6
500kg C3 H6F-C3-500kg-3B6
750kg C3 H6F-C3-750kg-3B6
1000kg C3 H6F-C3-1000kg-3B6
2000kg C3 H6F-C3-2000kg-3B6
Technical Specifications of H6F
Accuracy Class C3
Output Sensitivity ( FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) Kg 100, 150, 200, 250, 500, 750, 1000, 2000
Max. Number of Load Cell Intervals nLC 3000
Ratio of min. LC Verification Interval Y = Emax / Vmin 7500
Combined Error %FS ≤± 0.020
Minimum dead load Of Emax 0%
Safe overload Of Emax 150 %
Ultimate overload300 % Of Emax 300 %
Zero balance Of FS < ± 1.0 %
Excitation, recommended voltage V 5 ~ 12
Excitation maximum V 18
Input Resistance Ω 384 ± 4
Output Resistance Ω 351 ± 2
Insulation Resistance ≥5000 (at 50VDC)
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP66
Recommended Torque on Fixation Bolts Nm M12:75; M16:200
ATEX Classification (optional) II1G Ex ia II1C T4 II1D Ex iaD 20 T73°C II3G nL IIC T4
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6.2mm
Standard cable length: 3m
Shield not connected to element
Wiring Instruction:
Input (Positive) - Red
Sense (Positive) - Brown
Output (Positive) - Blue
Output (Negative) - White
Sense (Negative) - Black
Input (Negative) - Yellow
Dimension Wise Capacity:
Dimension Capacity B B1 H H1 H2 L L1 L2 M
50-200kg 44 24 75 50 30 156 112 14 M12
250-500kg 60 36 95 70 30 146 110 11 M12
750kg-2000kg 76 46 125 95 65 176 110 24 M16
Used in Single Point Platform, Automated servo belt system, PLC Application
৳0.00  Inc Tax
H8C Load Cell (H8C)
Short Description:
Nickel plated alloy steel IP67 shear beam load cell
Adhesive sealed
Suitable for platform weighing, bed weighing, etc.
High accuracy
High reliability
Current calibrated (SC-option)
Manufacturer:
Zemic Europe
Origin:
B.V Netherland
Available Models:
Capacity Accuracy Full Article Description
100kg C3/C4/C5 H8C-C3/C4/C5-100kg-4B(-SC-W6)
250kg C3/C4/C5 H8C-C3/C4/C5-250kg-4B(-SC-W6)
500kg C3/C4/C5 H8C-C3/C4/C5-500kg-4B(-SC-W6)
750kg C3/C4/C5 H8C-C3/C4/C5-750kg-4B(-SC-W6)
1ton C3/C4/C5 H8C-C3/C4/C5-1.0t-4B(-SC-W6)
1.5ton C3/C4/C5 H8C-C3/C4/C5-1.5t-4B(-SC-W6)
2ton C3/C4/C5 H8C-C3/C4/C5-2.0t-4B(-SC-W6)
2.5ton C3/C4/C5 H8C-C3/C4/C5-2.5t-6B(-SC-W6)
3ton C3/C4/C5 H8C-C3/C4/C5-3.0t-6B(-SC-W6)
5ton C3/C4/C5 H8C-C3/C4/C5-5.0t-6B(-SC-W6)
10ton C3/C4/C5 H8C-C3/C4/C5-10t-6B(-SC-W6)
Technical Specifications of H8C
Accuracy Class OIML R60 C3, OIML R60 C4, OIML R60 C5
Output Sensitivity ( FS ) mV/V 3.0 ± 0.003
Maximum Capacity ( Emax ) ton 0.1, 0.25, 0.5, 075, 1, 1.5, 2, 2.5, 3, 5, 10, 01, 0.25, 0.5, 0.75, 1, 1.5, 2, 2.5, 3, 5, 10
Max. Number of Load Cell Intervals nLC 3000, 4000, 5000
Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000, 20000, 18000
Combined Error %FS ≤± 0.023; ≤± 0.0175; ≤± 0.014
Creep Error (30 minutes) %FS ≤± 0.016; ≤± 0.012; ≤± 0.010
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.015; ≤± 0.010; ≤± 0.007
Temperature Effect on Sensitivity (STC) %FS/10°C ≤± 0.011; ≤± 0.009; ≤± 0.008
Zero balance %FS ≤± 1.0
Safe overload %FS 150
Ultimate Overload %FS 300
Maximum Deflection mm 0.1t – 0.2t: 0.3 0.5t – 5t: ~ 1.2 10t: 0.8
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 350 ± 3.5
Output Resistance Ω 350 ± 3.5
Insulation Resistance ≥5000
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 80
Load Cell Weight kg 0.1t – 2.0t: ~ 0.9; 2.5t – 5t: ~ 1.7; 10t: ~ 3.6
Element Material Nickel plated alloy steel
Ingress Protection (acc. to EN 60529) IP67
Recommended Torque on Fixation Bolts Nm M12: 100 M18:200 M24:700
ATEX Classification (optional) II 1G Ex ia IIC T4 Ga II 1D Ex ia IIIC T 200 135°C Da II 3G Ex ic IIC T4 Gc
Wiring:
Cable type: Shielded, 4 or 6 conductor cable, conductor AWG 22
Cable diameter: Ø 5.0mm
Cable length: 4m for 100kg – 2t; 6m for higher capacities
Shield not connected to element
Wiring Instruction:
For 4 Wire Loadcell:
Input(Positive) - Red
Output(Negative) - White
Input (Negative) - Black
Output(Positive) - Green
For 6 wire Loadcell:
Input(Positive) - Red
Sense (Positive) - Blue
Output(Negative) - White
Sense (Negative) - Yellow
Input (Negative) - Black
Output(Positive) - Green
Ordering Info:
Example: H8C – C3 – 1.0t – 4 – – BX – SC – XX
H8C Load Cell model
C3 Maximum load cell divisions
1.0t Nominal capacity (Emax) for Metric in t (ton)
4 Length of the cable in meters
Thread option. No mark is Metric thread and “Y” is Imperial thread
BX Cable option. No mark is 4 conductor cable and with a “6” a 6 conductor cable
SC Option SC (standard current)
XX Option XX. No mark is standard version, W4 is through loading hole, W6 is “T” end loading hole
Used in 4 Point Platform, Hopper Scale, Automated servo belt system, PLC Applications
৳0.00  Inc Tax
FM 1263 Load Cell (FM1263)
Short Description:
Aluminum-alloy IP65 single point load cell
Colourless anodized
Suitable for single and double load cells structured platform scales
Maximum platform size: 600 x 600 mm
A 1000 Ohm type available (R1) but is excluded from OIML
Manufacturer:
Fidelity Measurement Co. Ltd
Origin:
Assembled in Taiwan
Available Capacity:
Capacity Accuracy Full Article Description
50kg C3 L6G-C3-50kg-3G6
100kg C3 L6G-C3-100kg-3G6
150kg C3/C4 L6G-C3/C4-150kg-3G6
200kg C3/C4 L6G-C3/C4-200kg-3G6
250kg C3/C4 L6G-C3/C4-250kg-3G6
300kg C3/C4 L6G-C3/C4-300kg-3G6
500kg C3/C4 L6G-C3/C4-500kg-3G6
600kg C3/C4 L6G-C3/C4-600kg-3G6
Technical Specifications of FM1263
Accuracy Class OIML R60 C3, OIML R60 C4
Output Sensitivity ( FS ) mV/V 2.0 ± 0.2
Maximum Capacity ( Emax ) kg 50, 100, 150, 200, 250, 300, 500, 600; 150, 200, 250, 300, 500, 600
Max. Number of Load Cell Intervals nLC 3000, 4000
Ratio of min. LC Verification Interval Y = Emax / Vmin 10000, 15000
Combined Error %FS ≤± 0.02
Creep Error (30 minutes) %FS ≤± 0.02
Temperature Effect on Zero (ZTC) %FS/10°C ≤± 0.0230; ≤± 0.0175
Minimum dead load Of Emax 0%
Safe overload Of Emax 150 %
Ultimate Overload Of Emax 300 %
Zero balance Of FS < ± 2.0 %
Excitation, Recommended Voltage V 5 ~ 12
Excitation, Maximum Voltage V 18
Input Resistance Ω 409 ± 6
Output Resistance Ω 350 ± 3
Insulation Resistance >5000 (at 50VDC)
Compensated Temperature °C -10 ~ 40
Operating Temperature °C -35 ~ 65
Storage Temperature °C -40 ~ 70
Element Material Aluminum
Ingress Protection (acc. to EN 60529) IP65
Recommended Torque on Fixation Bolts Nm M8:25
Wiring:
Shielded, 6 conductor cable
Cable diameter: Ø6mm
Cable length: 3m
Shield connected to element
Cable jacket in PVC
Wiring Instruction:
Input(Positive) - Red
Sense(Positive) - Blue
Output(Positive) - Green
Output(Negative) - White
Sense(Negative) - Yellow
Input(Negative) - Black
Used in Single Point Platform, Automated servo belt system, PLC Application, Conveyer system, small floor scale platform.
৳0.00  Inc Tax
Per Page      1 - 9 of 9